| WATER IONIZERS PTV-AL; PTV-A | | | | | | | | 1. GENERAL PROVISIONS | | | | 1.1. Water ionizers PTV-AL(with timer), PTV-A – a devices in which ionized water is produced during water electrolysis. 1.2. Ionized water – alkaline and acid – is obtained in separate containers of water ionizer. 1.3. Alkaline water – has a weak negative electrical charge and has alkaline features. 1.4. Acid water– has a weak positive electrical charge and has acidic features. 1.5. Partition – wood fibre plate (plates) dividing the container into two parts, transmitting ions, but not allowing mixing of water. 1.6. The device meets electrical safety and safety requirements. | | | | 2. TECHNICAL DATA | | | | Technical characteristics are provided in the table. | | | | Parameters | Parameters value | | Vessel capacity, l | 1.4 | | Power supply voltage, V~ | 220 | | AC frequency, Hz | 50 | | Average duration of electrolysis when generating: | | | - ionized water, min | 25 | | Average power consumption when generating: | | | - ionized water, W | 100 | | Appliance total weight KL/K, not exceeding, kg | 1.3/1 | | Water temperature | 10 to 25oC | | Safety class (water penetration) | IPX 1 | | Dimensions, mm | 190 x 160 x 200 | | | | | 3. DESIGN AND PRINCIPLE OF OPERATION | | | | 3.1. The device consists of a lower container (1), a removable vessel (3) and an enclosure (9). (See pictures 1;2) 3.2. The lower container (1) is an electrolysis container. In the upper part of it two handles are installed. (2) A removable semi round vessel is built in the container (3), in which wood fibre partitions are set instead of the front wall (4). Partitions are fastened in the top with a fixer (5). On the inner side of the container and the vessel there are two marks: lower (6) indicates minimum and upper (7) – maximum water level. 3.3. In the enclosure (9) an electrical scheme is installed that is covered from inside with a plastic cover. In the cover flat electrodes (8;16) are fixed. Flat electrodes are meant for production of ionized water . On the board (11) located on the top of the enclosure three LEDs are mounted: the middle, green (13), lights when the plug of the device (12) is connected to the power supply socket. The red one (14) on the side lights when ionized water is produced. As well on the top of the enclosure four buttons for control of timer and working mode and time indicators are mounted (15) – PTV-AL and switch(15) – PTV-A. On the other side of the enclosure there is a cord with a plug. (12). | | |  | | Picture 1 General View of the PTV-AL | | |  | | Picture 2. General View of the PTV-A | | | | 3.4. Partitions (4) are mounted into special notches of the removable vessel (3) and fastened with a fixer (5). 3.5. During water electrolysis acid water is generated at the black electrode (8) and alkaline water - at the light one (16). Partitions (4) of the removable vessel (3) do not allow acid and alkaline waters to mix. | | | | 4. PROPERTIES OF IONIZED WATER AND ITS APPLICATION | | | | 4.1. Alkaline water, a natural stimulator, stimulates growth of plants, accelerates germination of seeds, flowering of domestic flowers, revives faded flowers, vegetables, etc.. It is a soft, odourless water having taste of rainwater. 4.2.Acid water, a natural bactericide, kills small pests, various microbes, bacteria, fungi. It is good in disinfecting soil, tare, fresh vegetables, fruit, etc.. It is a sourish water having typical acid and weak chlorine odour. 4.3. Alkaline and acid waters should be kept in tightly closed jars protecting them from direct sunlight. It not recommended to keep them in refrigerator. Alkaline water preserves its properties for up to 3 days and acid water - for up to 7 days. 4.4. Properties of ionized water are characterized by two indexes: ORP- oxidation- reduction potential and pH. ORP is characterized by positive or negative charges (mV) that respectively alkaline and acid waters charges. pH values can fluctuate between 0 to 14 units. Potable water is neutral, its pH is about 7,0. pH of catholyte fluctuates from 8,0 to 11,0 pH (the bigger this number, the more alkaline water is) and of pH of anolyte is from 6 to 2,4 pH (the smaller this number, the more acidic water is). 4.5. In the 1st table dependence of pH and ORP values on the working duration of the device is presented. These pH and ORP values have been obtained during testing of water used by the company- producer. In case of different composition of water values can differ. A minor difference of pH(+/-0,2-0,3) and ORP values does constitute practical influence. | | 1 The table | | | | Duration of work | ACID WATER | ALKALINE WATER
| | (electrolysis) of device | pH | ORP | | ORP | | (min) | (mv) | (mv) | | 5 | 6,12 | +48 | 8,74 | -103 | | 10 | 5,57 | +79 | 9,41 | -141 | | 15 | 3,72 | +185 | 9,83 | -165 | | 20 | 2,79 | +239 | 10,29 | -192 | | 25 | 2,54 | +252 | 10,33 | -194 | | 30 | 2,49 | +256 | 10,33 | -194 | | 35 | 2,41 | +261 | 10,33 | -195 | | 40 | 2,36 | +264 | 10,35 | -195 | | | | | 5. PRODUCTION OF IONIZED WATER | | PTV –AL; A 5.1. Holding the lower container (1) on its handles (2) remove the enclosure (9) of the device. 5.2. Make sure the partitions of the removable vessel (4) are tightly inserted into the notches of the vessel. 5.3. Pour cold water from tap: first of all into the removable vessel (3) then into the lower vessel (1) up to the lower marks (6). 5.4. Put the enclosure (9) on the lower container (1) so that the dark electrode (8) would get into the removable vessel.(3). PTV -AL 5.5. Connect the cord with the plug (12) to the socket. On the enclosure (9) green indicator (13) lights up and in the indicator of timer (15) - letter A shows.. Set the working duration of the device according to the table 1. 5.6. Pushing the control button (15) indicated by arrow ↑ to set the required time of electrolysis. To reduce the set time push the button (15) indicated by the arrow ↓. Push the button START. Red indicator (14) lights up indicated by letter A. The device starts working. After the set time passes the device switches off automatically. To make a premature cancellation of the work of the device push the button STOP. After the work of the device is finished (when the time of switching on is longer than 3 minutes) a sound signal is given. It is switched off by pushing the button STOP. PTV – A 5.7. Connect the cord with the plug (12) to the socket. On the enclosure (9) green indicator (13) lights up. Turn on the switch (15). Green (13) and red A (14) indicators must light. Set the working duration of the device according to the table 1. After the set time passes, turn off the switch (15),p ull the plug of the cord (12) from a socket 5.8. Pull the plug of the cord (12) from a socket, take off the enclosure (9), pour out from the removable vessel (3) the acid water and then alkaline water into prepared, tightly closed jars. 5.9. Just produced alkaline water is turbid and sometimes foamy. After pouring alkaline water into a jar, sediments and foam precipitate on the bottom, water becomes clear and suitable for using (the amount of sediments precipitated shows the level of contamination of water). 5.10. Just produced acid water has a slight acidic and chlorine odour and is sourish. 5.11. When working with the device water can heat up to 40 degrees. 5.12. Wash the removable vessel (3) and lower container (1) with water. It is PROHIBITED to wash with water the enclosure (9) containing the electric part! 5.13. Clean the light electrode (16) with soft cloth dipped in vinegar. It is not necessary to clean the dark electrode (8). 5.14. Dry the lower container (1), the enclosure (9) and removable vessel (3) without taking out the partitions. After the partitions (4) fully dry assemble the device and store it in dry place.
| | | Notes: 1.When producing ionized water for the first time in the new device or when replacing wood fibre partitions in the already used device with the new ones after pouring water to the removable vessel (3) and the lower container (1) it is neccesary to wait for 30-40 minutes in order partitions get damp and then pour the ionized water out (do not use). 2.Wood fibre partitions swell and can contort (during drying they don't get right). It does not influence the quality of ionized water. It is important that the partitions do not leak. 3. Should damage of the coating layer of the dark electrode occur, the electrode must be replaced. | |
 |
|
|
|
|
|
 |
|
 |
 |
|
 |
|
|
|